Trendsic Platform Service

<back to all web services

InspectionDetailRequest

Requires Authentication
The following routes are available for this service:
GET,OPTIONS/v1/inspections/{InspectionUID}
namespace CRM.AgencyPlatform.API.Internal

open System
open System.IO
open System.Collections
open System.Collections.Generic
open System.Runtime.Serialization
open ServiceStack
open ServiceStack.DataAnnotations

    [<AllowNullLiteral>]
    type InspectionPhoto() = 
        member val AttachmentId:Guid = new Guid() with get,set
        member val FileName:String = null with get,set
        member val Url:String = null with get,set
        member val CreatedBy:String = null with get,set
        member val CreatedDate:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val HasAnnotation:Boolean = new Boolean() with get,set
        member val AnnotatedAttachmentId:Nullable<Guid> = new Nullable<Guid>() with get,set
        member val AnnotatedUrl:String = null with get,set

    [<AllowNullLiteral>]
    type InspectionItem() = 
        member val InspectionItemID:Int32 = new Int32() with get,set
        member val InspectionID:Int32 = new Int32() with get,set
        member val Seq:Int32 = new Int32() with get,set
        member val Section:String = null with get,set
        member val Prompt:String = null with get,set
        member val ResponseType:String = null with get,set
        member val IsRequired:Boolean = new Boolean() with get,set
        member val Unit:String = null with get,set
        member val Guidance:String = null with get,set
        member val Result:String = null with get,set
        member val Value:String = null with get,set
        member val Notes:String = null with get,set
        member val PhotoCount:Int32 = new Int32() with get,set
        member val LinkedPunchItemID:Nullable<Int32> = new Nullable<Int32>() with get,set
        member val LinkedPunchNo:String = null with get,set
        member val LinkedPunchStatus:String = null with get,set
        member val LinkedNcrID:Nullable<Int32> = new Nullable<Int32>() with get,set
        member val LinkedNcrNo:String = null with get,set
        member val LinkedActionID:Nullable<Int32> = new Nullable<Int32>() with get,set
        member val AnsweredBy:String = null with get,set
        member val AnsweredAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val Photos:ResizeArray<InspectionPhoto> = new ResizeArray<InspectionPhoto>() with get,set

    [<AllowNullLiteral>]
    type InspectionRequest() = 
        member val InspectionRequestID:Int32 = new Int32() with get,set
        member val InspectionID:Int32 = new Int32() with get,set
        member val Agency:String = null with get,set
        member val ContactName:String = null with get,set
        member val ContactPhone:String = null with get,set
        member val PermitNo:String = null with get,set
        member val RequestedDate:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val RequestedWindow:String = null with get,set
        member val Status:String = null with get,set
        member val ConfirmationNo:String = null with get,set
        member val Outcome:String = null with get,set
        member val CreatedBy:String = null with get,set
        member val CreatedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val UpdatedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set

    [<AllowNullLiteral>]
    type SignatureRecord() = 
        member val SignatureRecordID:Int32 = new Int32() with get,set
        member val EntityType:String = null with get,set
        member val EntityID:Int32 = new Int32() with get,set
        member val Role:String = null with get,set
        member val SignerName:String = null with get,set
        member val SignerContactID:Nullable<Int32> = new Nullable<Int32>() with get,set
        member val SignerUserId:String = null with get,set
        member val Method:String = null with get,set
        member val ImageAttachmentId:Nullable<Guid> = new Nullable<Guid>() with get,set
        member val ImageUrl:String = null with get,set
        member val ImageHash:String = null with get,set
        member val DocumentHash:String = null with get,set
        member val ConsentText:String = null with get,set
        member val IpAddress:String = null with get,set
        member val UserAgent:String = null with get,set
        member val SignedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set

    [<AllowNullLiteral>]
    type Inspection() = 
        member val InspectionID:Int32 = new Int32() with get,set
        member val InspectionUID:Guid = new Guid() with get,set
        member val ProjectID:Int32 = new Int32() with get,set
        member val ProjectName:String = null with get,set
        member val JobID:Nullable<Int32> = new Nullable<Int32>() with get,set
        member val JobName:String = null with get,set
        member val InspectionNo:String = null with get,set
        member val Type:String = null with get,set
        member val Title:String = null with get,set
        member val Status:String = null with get,set
        member val TemplateUID:Nullable<Guid> = new Nullable<Guid>() with get,set
        member val TemplateVersionNo:Nullable<Int32> = new Nullable<Int32>() with get,set
        member val ScheduledFor:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val StartedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val CompletedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val ClosedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val InspectorContactID:Nullable<Int32> = new Nullable<Int32>() with get,set
        member val InspectorName:String = null with get,set
        member val AgencyName:String = null with get,set
        member val PermitNo:String = null with get,set
        member val LocationText:String = null with get,set
        member val Notes:String = null with get,set
        member val WeatherJson:String = null with get,set
        member val ItemsTotal:Int32 = new Int32() with get,set
        member val ItemsPassed:Int32 = new Int32() with get,set
        member val ItemsFailed:Int32 = new Int32() with get,set
        member val Outcome:String = null with get,set
        member val OutcomeNotes:String = null with get,set
        member val ReinspectionOfInspectionID:Nullable<Int32> = new Nullable<Int32>() with get,set
        member val QcHoldPointID:Nullable<Int32> = new Nullable<Int32>() with get,set
        member val ReportAttachmentId:Nullable<Guid> = new Nullable<Guid>() with get,set
        member val RequestCount:Int32 = new Int32() with get,set
        member val SignatureCount:Int32 = new Int32() with get,set
        member val CreatedBy:String = null with get,set
        member val CreatedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val UpdatedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
        member val Items:ResizeArray<InspectionItem> = new ResizeArray<InspectionItem>() with get,set
        member val Requests:ResizeArray<InspectionRequest> = new ResizeArray<InspectionRequest>() with get,set
        member val Signatures:ResizeArray<SignatureRecord> = new ResizeArray<SignatureRecord>() with get,set
        member val Actions:ResizeArray<String> = new ResizeArray<String>() with get,set

    [<AllowNullLiteral>]
    type InspectionResponse() = 
        member val ResponseStatus:ResponseStatus = null with get,set
        member val Inspection:Inspection = null with get,set

    [<AllowNullLiteral>]
    type InspectionDetailRequest() = 
        member val InspectionUID:Guid = new Guid() with get,set

F# InspectionDetailRequest DTOs

To override the Content-type in your clients, use the HTTP Accept Header, append the .csv suffix or ?format=csv

HTTP + CSV

The following are sample HTTP requests and responses. The placeholders shown need to be replaced with actual values.

GET /v1/inspections/{InspectionUID} HTTP/1.1 
Host: api.dev.dynamics.trendsic.com 
Accept: text/csv
HTTP/1.1 200 OK
Content-Type: text/csv
Content-Length: length

{"ResponseStatus":{"ErrorCode":"String","Message":"String","StackTrace":"String","Errors":[{"ErrorCode":"String","FieldName":"String","Message":"String","Meta":{"String":"String"}}],"Meta":{"String":"String"}},"Inspection":{"InspectionID":0,"InspectionUID":"00000000000000000000000000000000","ProjectID":0,"ProjectName":"String","JobID":0,"JobName":"String","InspectionNo":"String","Type":"String","Title":"String","Status":"String","TemplateUID":"00000000000000000000000000000000","TemplateVersionNo":0,"ScheduledFor":"0001-01-01T00:00:00.0000000","StartedAt":"0001-01-01T00:00:00.0000000","CompletedAt":"0001-01-01T00:00:00.0000000","ClosedAt":"0001-01-01T00:00:00.0000000","InspectorContactID":0,"InspectorName":"String","AgencyName":"String","PermitNo":"String","LocationText":"String","Notes":"String","WeatherJson":"String","ItemsTotal":0,"ItemsPassed":0,"ItemsFailed":0,"Outcome":"String","OutcomeNotes":"String","ReinspectionOfInspectionID":0,"QcHoldPointID":0,"ReportAttachmentId":"00000000000000000000000000000000","RequestCount":0,"SignatureCount":0,"CreatedBy":"String","CreatedAt":"0001-01-01T00:00:00.0000000","UpdatedAt":"0001-01-01T00:00:00.0000000","Items":[{"InspectionItemID":0,"InspectionID":0,"Seq":0,"Section":"String","Prompt":"String","ResponseType":"String","IsRequired":false,"Unit":"String","Guidance":"String","Result":"String","Value":"String","Notes":"String","PhotoCount":0,"LinkedPunchItemID":0,"LinkedPunchNo":"String","LinkedPunchStatus":"String","LinkedNcrID":0,"LinkedNcrNo":"String","LinkedActionID":0,"AnsweredBy":"String","AnsweredAt":"0001-01-01T00:00:00.0000000","Photos":[{"AttachmentId":"00000000000000000000000000000000","FileName":"String","Url":"String","CreatedBy":"String","CreatedDate":"0001-01-01T00:00:00.0000000","HasAnnotation":false,"AnnotatedAttachmentId":"00000000000000000000000000000000","AnnotatedUrl":"String"}]}],"Requests":[{"InspectionRequestID":0,"InspectionID":0,"Agency":"String","ContactName":"String","ContactPhone":"String","PermitNo":"String","RequestedDate":"0001-01-01T00:00:00.0000000","RequestedWindow":"String","Status":"String","ConfirmationNo":"String","Outcome":"String","CreatedBy":"String","CreatedAt":"0001-01-01T00:00:00.0000000","UpdatedAt":"0001-01-01T00:00:00.0000000"}],"Signatures":[{"SignatureRecordID":0,"EntityType":"String","EntityID":0,"Role":"String","SignerName":"String","SignerContactID":0,"SignerUserId":"String","Method":"String","ImageAttachmentId":"00000000000000000000000000000000","ImageUrl":"String","ImageHash":"String","DocumentHash":"String","ConsentText":"String","IpAddress":"String","UserAgent":"String","SignedAt":"0001-01-01T00:00:00.0000000"}],"Actions":["String"]}}