Trendsic Platform Service

<back to all web services

InspectionDetailRequest

Requires Authentication
The following routes are available for this service:
GET,OPTIONS/v1/inspections/{InspectionUID}

export class InspectionPhoto
{
    public AttachmentId: string;
    public FileName: string;
    public Url: string;
    public CreatedBy: string;
    public CreatedDate?: string;
    public HasAnnotation: boolean;
    public AnnotatedAttachmentId?: string;
    public AnnotatedUrl: string;

    public constructor(init?: Partial<InspectionPhoto>) { (Object as any).assign(this, init); }
}

export class InspectionItem
{
    public InspectionItemID: number;
    public InspectionID: number;
    public Seq: number;
    public Section: string;
    public Prompt: string;
    public ResponseType: string;
    public IsRequired: boolean;
    public Unit: string;
    public Guidance: string;
    public Result: string;
    public Value: string;
    public Notes: string;
    public PhotoCount: number;
    public LinkedPunchItemID?: number;
    public LinkedPunchNo: string;
    public LinkedPunchStatus: string;
    public LinkedNcrID?: number;
    public LinkedNcrNo: string;
    public LinkedActionID?: number;
    public AnsweredBy: string;
    public AnsweredAt?: string;
    public Photos: InspectionPhoto[] = [];

    public constructor(init?: Partial<InspectionItem>) { (Object as any).assign(this, init); }
}

export class InspectionRequest
{
    public InspectionRequestID: number;
    public InspectionID: number;
    public Agency: string;
    public ContactName: string;
    public ContactPhone: string;
    public PermitNo: string;
    public RequestedDate?: string;
    public RequestedWindow: string;
    public Status: string;
    public ConfirmationNo: string;
    public Outcome: string;
    public CreatedBy: string;
    public CreatedAt?: string;
    public UpdatedAt?: string;

    public constructor(init?: Partial<InspectionRequest>) { (Object as any).assign(this, init); }
}

export class SignatureRecord
{
    public SignatureRecordID: number;
    public EntityType: string;
    public EntityID: number;
    public Role: string;
    public SignerName: string;
    public SignerContactID?: number;
    public SignerUserId: string;
    public Method: string;
    public ImageAttachmentId?: string;
    public ImageUrl: string;
    public ImageHash: string;
    public DocumentHash: string;
    public ConsentText: string;
    public IpAddress: string;
    public UserAgent: string;
    public SignedAt?: string;

    public constructor(init?: Partial<SignatureRecord>) { (Object as any).assign(this, init); }
}

export class Inspection
{
    public InspectionID: number;
    public InspectionUID: string;
    public ProjectID: number;
    public ProjectName: string;
    public JobID?: number;
    public JobName: string;
    public InspectionNo: string;
    public Type: string;
    public Title: string;
    public Status: string;
    public TemplateUID?: string;
    public TemplateVersionNo?: number;
    public ScheduledFor?: string;
    public StartedAt?: string;
    public CompletedAt?: string;
    public ClosedAt?: string;
    public InspectorContactID?: number;
    public InspectorName: string;
    public AgencyName: string;
    public PermitNo: string;
    public LocationText: string;
    public Notes: string;
    public WeatherJson: string;
    public ItemsTotal: number;
    public ItemsPassed: number;
    public ItemsFailed: number;
    public Outcome: string;
    public OutcomeNotes: string;
    public ReinspectionOfInspectionID?: number;
    public QcHoldPointID?: number;
    public ReportAttachmentId?: string;
    public RequestCount: number;
    public SignatureCount: number;
    public CreatedBy: string;
    public CreatedAt?: string;
    public UpdatedAt?: string;
    public Items: InspectionItem[] = [];
    public Requests: InspectionRequest[] = [];
    public Signatures: SignatureRecord[] = [];
    public Actions: string[] = [];

    public constructor(init?: Partial<Inspection>) { (Object as any).assign(this, init); }
}

export class InspectionResponse
{
    public ResponseStatus: ResponseStatus;
    public Inspection: Inspection;

    public constructor(init?: Partial<InspectionResponse>) { (Object as any).assign(this, init); }
}

export class InspectionDetailRequest
{
    public InspectionUID: string;

    public constructor(init?: Partial<InspectionDetailRequest>) { (Object as any).assign(this, init); }
}

TypeScript InspectionDetailRequest DTOs

To override the Content-type in your clients, use the HTTP Accept Header, append the .json suffix or ?format=json

To embed the response in a jsonp callback, append ?callback=myCallback

HTTP + JSON

The following are sample HTTP requests and responses. The placeholders shown need to be replaced with actual values.

GET /v1/inspections/{InspectionUID} HTTP/1.1 
Host: api.dev.dynamics.trendsic.com 
Accept: application/json
HTTP/1.1 200 OK
Content-Type: application/json
Content-Length: length

{"ResponseStatus":{"ErrorCode":"String","Message":"String","StackTrace":"String","Errors":[{"ErrorCode":"String","FieldName":"String","Message":"String","Meta":{"String":"String"}}],"Meta":{"String":"String"}},"Inspection":{"InspectionID":0,"InspectionUID":"00000000000000000000000000000000","ProjectID":0,"ProjectName":"String","JobID":0,"JobName":"String","InspectionNo":"String","Type":"String","Title":"String","Status":"String","TemplateUID":"00000000000000000000000000000000","TemplateVersionNo":0,"ScheduledFor":"0001-01-01T00:00:00.0000000","StartedAt":"0001-01-01T00:00:00.0000000","CompletedAt":"0001-01-01T00:00:00.0000000","ClosedAt":"0001-01-01T00:00:00.0000000","InspectorContactID":0,"InspectorName":"String","AgencyName":"String","PermitNo":"String","LocationText":"String","Notes":"String","WeatherJson":"String","ItemsTotal":0,"ItemsPassed":0,"ItemsFailed":0,"Outcome":"String","OutcomeNotes":"String","ReinspectionOfInspectionID":0,"QcHoldPointID":0,"ReportAttachmentId":"00000000000000000000000000000000","RequestCount":0,"SignatureCount":0,"CreatedBy":"String","CreatedAt":"0001-01-01T00:00:00.0000000","UpdatedAt":"0001-01-01T00:00:00.0000000","Items":[{"InspectionItemID":0,"InspectionID":0,"Seq":0,"Section":"String","Prompt":"String","ResponseType":"String","IsRequired":false,"Unit":"String","Guidance":"String","Result":"String","Value":"String","Notes":"String","PhotoCount":0,"LinkedPunchItemID":0,"LinkedPunchNo":"String","LinkedPunchStatus":"String","LinkedNcrID":0,"LinkedNcrNo":"String","LinkedActionID":0,"AnsweredBy":"String","AnsweredAt":"0001-01-01T00:00:00.0000000","Photos":[{"AttachmentId":"00000000000000000000000000000000","FileName":"String","Url":"String","CreatedBy":"String","CreatedDate":"0001-01-01T00:00:00.0000000","HasAnnotation":false,"AnnotatedAttachmentId":"00000000000000000000000000000000","AnnotatedUrl":"String"}]}],"Requests":[{"InspectionRequestID":0,"InspectionID":0,"Agency":"String","ContactName":"String","ContactPhone":"String","PermitNo":"String","RequestedDate":"0001-01-01T00:00:00.0000000","RequestedWindow":"String","Status":"String","ConfirmationNo":"String","Outcome":"String","CreatedBy":"String","CreatedAt":"0001-01-01T00:00:00.0000000","UpdatedAt":"0001-01-01T00:00:00.0000000"}],"Signatures":[{"SignatureRecordID":0,"EntityType":"String","EntityID":0,"Role":"String","SignerName":"String","SignerContactID":0,"SignerUserId":"String","Method":"String","ImageAttachmentId":"00000000000000000000000000000000","ImageUrl":"String","ImageHash":"String","DocumentHash":"String","ConsentText":"String","IpAddress":"String","UserAgent":"String","SignedAt":"0001-01-01T00:00:00.0000000"}],"Actions":["String"]}}