| GET,OPTIONS | /v1/inspections/{InspectionUID} |
|---|
namespace CRM.AgencyPlatform.API.Internal
open System
open System.IO
open System.Collections
open System.Collections.Generic
open System.Runtime.Serialization
open ServiceStack
open ServiceStack.DataAnnotations
[<AllowNullLiteral>]
type InspectionPhoto() =
member val AttachmentId:Guid = new Guid() with get,set
member val FileName:String = null with get,set
member val Url:String = null with get,set
member val CreatedBy:String = null with get,set
member val CreatedDate:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val HasAnnotation:Boolean = new Boolean() with get,set
member val AnnotatedAttachmentId:Nullable<Guid> = new Nullable<Guid>() with get,set
member val AnnotatedUrl:String = null with get,set
[<AllowNullLiteral>]
type InspectionItem() =
member val InspectionItemID:Int32 = new Int32() with get,set
member val InspectionID:Int32 = new Int32() with get,set
member val Seq:Int32 = new Int32() with get,set
member val Section:String = null with get,set
member val Prompt:String = null with get,set
member val ResponseType:String = null with get,set
member val IsRequired:Boolean = new Boolean() with get,set
member val Unit:String = null with get,set
member val Guidance:String = null with get,set
member val Result:String = null with get,set
member val Value:String = null with get,set
member val Notes:String = null with get,set
member val PhotoCount:Int32 = new Int32() with get,set
member val LinkedPunchItemID:Nullable<Int32> = new Nullable<Int32>() with get,set
member val LinkedPunchNo:String = null with get,set
member val LinkedPunchStatus:String = null with get,set
member val LinkedNcrID:Nullable<Int32> = new Nullable<Int32>() with get,set
member val LinkedNcrNo:String = null with get,set
member val LinkedActionID:Nullable<Int32> = new Nullable<Int32>() with get,set
member val AnsweredBy:String = null with get,set
member val AnsweredAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val Photos:ResizeArray<InspectionPhoto> = new ResizeArray<InspectionPhoto>() with get,set
[<AllowNullLiteral>]
type InspectionRequest() =
member val InspectionRequestID:Int32 = new Int32() with get,set
member val InspectionID:Int32 = new Int32() with get,set
member val Agency:String = null with get,set
member val ContactName:String = null with get,set
member val ContactPhone:String = null with get,set
member val PermitNo:String = null with get,set
member val RequestedDate:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val RequestedWindow:String = null with get,set
member val Status:String = null with get,set
member val ConfirmationNo:String = null with get,set
member val Outcome:String = null with get,set
member val CreatedBy:String = null with get,set
member val CreatedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val UpdatedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
[<AllowNullLiteral>]
type SignatureRecord() =
member val SignatureRecordID:Int32 = new Int32() with get,set
member val EntityType:String = null with get,set
member val EntityID:Int32 = new Int32() with get,set
member val Role:String = null with get,set
member val SignerName:String = null with get,set
member val SignerContactID:Nullable<Int32> = new Nullable<Int32>() with get,set
member val SignerUserId:String = null with get,set
member val Method:String = null with get,set
member val ImageAttachmentId:Nullable<Guid> = new Nullable<Guid>() with get,set
member val ImageUrl:String = null with get,set
member val ImageHash:String = null with get,set
member val DocumentHash:String = null with get,set
member val ConsentText:String = null with get,set
member val IpAddress:String = null with get,set
member val UserAgent:String = null with get,set
member val SignedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
[<AllowNullLiteral>]
type Inspection() =
member val InspectionID:Int32 = new Int32() with get,set
member val InspectionUID:Guid = new Guid() with get,set
member val ProjectID:Int32 = new Int32() with get,set
member val ProjectName:String = null with get,set
member val JobID:Nullable<Int32> = new Nullable<Int32>() with get,set
member val JobName:String = null with get,set
member val InspectionNo:String = null with get,set
member val Type:String = null with get,set
member val Title:String = null with get,set
member val Status:String = null with get,set
member val TemplateUID:Nullable<Guid> = new Nullable<Guid>() with get,set
member val TemplateVersionNo:Nullable<Int32> = new Nullable<Int32>() with get,set
member val ScheduledFor:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val StartedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val CompletedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val ClosedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val InspectorContactID:Nullable<Int32> = new Nullable<Int32>() with get,set
member val InspectorName:String = null with get,set
member val AgencyName:String = null with get,set
member val PermitNo:String = null with get,set
member val LocationText:String = null with get,set
member val Notes:String = null with get,set
member val WeatherJson:String = null with get,set
member val ItemsTotal:Int32 = new Int32() with get,set
member val ItemsPassed:Int32 = new Int32() with get,set
member val ItemsFailed:Int32 = new Int32() with get,set
member val Outcome:String = null with get,set
member val OutcomeNotes:String = null with get,set
member val ReinspectionOfInspectionID:Nullable<Int32> = new Nullable<Int32>() with get,set
member val QcHoldPointID:Nullable<Int32> = new Nullable<Int32>() with get,set
member val ReportAttachmentId:Nullable<Guid> = new Nullable<Guid>() with get,set
member val RequestCount:Int32 = new Int32() with get,set
member val SignatureCount:Int32 = new Int32() with get,set
member val CreatedBy:String = null with get,set
member val CreatedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val UpdatedAt:Nullable<DateTime> = new Nullable<DateTime>() with get,set
member val Items:ResizeArray<InspectionItem> = new ResizeArray<InspectionItem>() with get,set
member val Requests:ResizeArray<InspectionRequest> = new ResizeArray<InspectionRequest>() with get,set
member val Signatures:ResizeArray<SignatureRecord> = new ResizeArray<SignatureRecord>() with get,set
member val Actions:ResizeArray<String> = new ResizeArray<String>() with get,set
[<AllowNullLiteral>]
type InspectionResponse() =
member val ResponseStatus:ResponseStatus = null with get,set
member val Inspection:Inspection = null with get,set
[<AllowNullLiteral>]
type InspectionDetailRequest() =
member val InspectionUID:Guid = new Guid() with get,set
F# InspectionDetailRequest DTOs
To override the Content-type in your clients, use the HTTP Accept Header, append the .jsv suffix or ?format=jsv
The following are sample HTTP requests and responses. The placeholders shown need to be replaced with actual values.
GET /v1/inspections/{InspectionUID} HTTP/1.1
Host: api.dev.dynamics.trendsic.com
Accept: text/jsv
HTTP/1.1 200 OK
Content-Type: text/jsv
Content-Length: length
{
ResponseStatus:
{
ErrorCode: String,
Message: String,
StackTrace: String,
Errors:
[
{
ErrorCode: String,
FieldName: String,
Message: String,
Meta:
{
String: String
}
}
],
Meta:
{
String: String
}
},
Inspection:
{
InspectionID: 0,
InspectionUID: 00000000000000000000000000000000,
ProjectID: 0,
ProjectName: String,
JobID: 0,
JobName: String,
InspectionNo: String,
Type: String,
Title: String,
Status: String,
TemplateUID: 00000000000000000000000000000000,
TemplateVersionNo: 0,
ScheduledFor: 0001-01-01,
StartedAt: 0001-01-01,
CompletedAt: 0001-01-01,
ClosedAt: 0001-01-01,
InspectorContactID: 0,
InspectorName: String,
AgencyName: String,
PermitNo: String,
LocationText: String,
Notes: String,
WeatherJson: String,
ItemsTotal: 0,
ItemsPassed: 0,
ItemsFailed: 0,
Outcome: String,
OutcomeNotes: String,
ReinspectionOfInspectionID: 0,
QcHoldPointID: 0,
ReportAttachmentId: 00000000000000000000000000000000,
RequestCount: 0,
SignatureCount: 0,
CreatedBy: String,
CreatedAt: 0001-01-01,
UpdatedAt: 0001-01-01,
Items:
[
{
InspectionItemID: 0,
InspectionID: 0,
Seq: 0,
Section: String,
Prompt: String,
ResponseType: String,
IsRequired: False,
Unit: String,
Guidance: String,
Result: String,
Value: String,
Notes: String,
PhotoCount: 0,
LinkedPunchItemID: 0,
LinkedPunchNo: String,
LinkedPunchStatus: String,
LinkedNcrID: 0,
LinkedNcrNo: String,
LinkedActionID: 0,
AnsweredBy: String,
AnsweredAt: 0001-01-01,
Photos:
[
{
AttachmentId: 00000000000000000000000000000000,
FileName: String,
Url: String,
CreatedBy: String,
CreatedDate: 0001-01-01,
HasAnnotation: False,
AnnotatedAttachmentId: 00000000000000000000000000000000,
AnnotatedUrl: String
}
]
}
],
Requests:
[
{
InspectionRequestID: 0,
InspectionID: 0,
Agency: String,
ContactName: String,
ContactPhone: String,
PermitNo: String,
RequestedDate: 0001-01-01,
RequestedWindow: String,
Status: String,
ConfirmationNo: String,
Outcome: String,
CreatedBy: String,
CreatedAt: 0001-01-01,
UpdatedAt: 0001-01-01
}
],
Signatures:
[
{
SignatureRecordID: 0,
EntityType: String,
EntityID: 0,
Role: String,
SignerName: String,
SignerContactID: 0,
SignerUserId: String,
Method: String,
ImageAttachmentId: 00000000000000000000000000000000,
ImageUrl: String,
ImageHash: String,
DocumentHash: String,
ConsentText: String,
IpAddress: String,
UserAgent: String,
SignedAt: 0001-01-01
}
],
Actions:
[
String
]
}
}