| GET,OPTIONS | /v1/inspections/{InspectionUID} |
|---|
"use strict";
export class InspectionPhoto {
/** @param {{AttachmentId?:string,FileName?:string,Url?:string,CreatedBy?:string,CreatedDate?:string,HasAnnotation?:boolean,AnnotatedAttachmentId?:string,AnnotatedUrl?:string}} [init] */
constructor(init) { Object.assign(this, init) }
/** @type {string} */
AttachmentId;
/** @type {string} */
FileName;
/** @type {string} */
Url;
/** @type {string} */
CreatedBy;
/** @type {?string} */
CreatedDate;
/** @type {boolean} */
HasAnnotation;
/** @type {?string} */
AnnotatedAttachmentId;
/** @type {string} */
AnnotatedUrl;
}
export class InspectionItem {
/** @param {{InspectionItemID?:number,InspectionID?:number,Seq?:number,Section?:string,Prompt?:string,ResponseType?:string,IsRequired?:boolean,Unit?:string,Guidance?:string,Result?:string,Value?:string,Notes?:string,PhotoCount?:number,LinkedPunchItemID?:number,LinkedPunchNo?:string,LinkedPunchStatus?:string,LinkedNcrID?:number,LinkedNcrNo?:string,LinkedActionID?:number,AnsweredBy?:string,AnsweredAt?:string,Photos?:InspectionPhoto[]}} [init] */
constructor(init) { Object.assign(this, init) }
/** @type {number} */
InspectionItemID;
/** @type {number} */
InspectionID;
/** @type {number} */
Seq;
/** @type {string} */
Section;
/** @type {string} */
Prompt;
/** @type {string} */
ResponseType;
/** @type {boolean} */
IsRequired;
/** @type {string} */
Unit;
/** @type {string} */
Guidance;
/** @type {string} */
Result;
/** @type {string} */
Value;
/** @type {string} */
Notes;
/** @type {number} */
PhotoCount;
/** @type {?number} */
LinkedPunchItemID;
/** @type {string} */
LinkedPunchNo;
/** @type {string} */
LinkedPunchStatus;
/** @type {?number} */
LinkedNcrID;
/** @type {string} */
LinkedNcrNo;
/** @type {?number} */
LinkedActionID;
/** @type {string} */
AnsweredBy;
/** @type {?string} */
AnsweredAt;
/** @type {InspectionPhoto[]} */
Photos = [];
}
export class InspectionRequest {
/** @param {{InspectionRequestID?:number,InspectionID?:number,Agency?:string,ContactName?:string,ContactPhone?:string,PermitNo?:string,RequestedDate?:string,RequestedWindow?:string,Status?:string,ConfirmationNo?:string,Outcome?:string,CreatedBy?:string,CreatedAt?:string,UpdatedAt?:string}} [init] */
constructor(init) { Object.assign(this, init) }
/** @type {number} */
InspectionRequestID;
/** @type {number} */
InspectionID;
/** @type {string} */
Agency;
/** @type {string} */
ContactName;
/** @type {string} */
ContactPhone;
/** @type {string} */
PermitNo;
/** @type {?string} */
RequestedDate;
/** @type {string} */
RequestedWindow;
/** @type {string} */
Status;
/** @type {string} */
ConfirmationNo;
/** @type {string} */
Outcome;
/** @type {string} */
CreatedBy;
/** @type {?string} */
CreatedAt;
/** @type {?string} */
UpdatedAt;
}
export class SignatureRecord {
/** @param {{SignatureRecordID?:number,EntityType?:string,EntityID?:number,Role?:string,SignerName?:string,SignerContactID?:number,SignerUserId?:string,Method?:string,ImageAttachmentId?:string,ImageUrl?:string,ImageHash?:string,DocumentHash?:string,ConsentText?:string,IpAddress?:string,UserAgent?:string,SignedAt?:string}} [init] */
constructor(init) { Object.assign(this, init) }
/** @type {number} */
SignatureRecordID;
/** @type {string} */
EntityType;
/** @type {number} */
EntityID;
/** @type {string} */
Role;
/** @type {string} */
SignerName;
/** @type {?number} */
SignerContactID;
/** @type {string} */
SignerUserId;
/** @type {string} */
Method;
/** @type {?string} */
ImageAttachmentId;
/** @type {string} */
ImageUrl;
/** @type {string} */
ImageHash;
/** @type {string} */
DocumentHash;
/** @type {string} */
ConsentText;
/** @type {string} */
IpAddress;
/** @type {string} */
UserAgent;
/** @type {?string} */
SignedAt;
}
export class Inspection {
/** @param {{InspectionID?:number,InspectionUID?:string,ProjectID?:number,ProjectName?:string,JobID?:number,JobName?:string,InspectionNo?:string,Type?:string,Title?:string,Status?:string,TemplateUID?:string,TemplateVersionNo?:number,ScheduledFor?:string,StartedAt?:string,CompletedAt?:string,ClosedAt?:string,InspectorContactID?:number,InspectorName?:string,AgencyName?:string,PermitNo?:string,LocationText?:string,Notes?:string,WeatherJson?:string,ItemsTotal?:number,ItemsPassed?:number,ItemsFailed?:number,Outcome?:string,OutcomeNotes?:string,ReinspectionOfInspectionID?:number,QcHoldPointID?:number,ReportAttachmentId?:string,RequestCount?:number,SignatureCount?:number,CreatedBy?:string,CreatedAt?:string,UpdatedAt?:string,Items?:InspectionItem[],Requests?:InspectionRequest[],Signatures?:SignatureRecord[],Actions?:string[]}} [init] */
constructor(init) { Object.assign(this, init) }
/** @type {number} */
InspectionID;
/** @type {string} */
InspectionUID;
/** @type {number} */
ProjectID;
/** @type {string} */
ProjectName;
/** @type {?number} */
JobID;
/** @type {string} */
JobName;
/** @type {string} */
InspectionNo;
/** @type {string} */
Type;
/** @type {string} */
Title;
/** @type {string} */
Status;
/** @type {?string} */
TemplateUID;
/** @type {?number} */
TemplateVersionNo;
/** @type {?string} */
ScheduledFor;
/** @type {?string} */
StartedAt;
/** @type {?string} */
CompletedAt;
/** @type {?string} */
ClosedAt;
/** @type {?number} */
InspectorContactID;
/** @type {string} */
InspectorName;
/** @type {string} */
AgencyName;
/** @type {string} */
PermitNo;
/** @type {string} */
LocationText;
/** @type {string} */
Notes;
/** @type {string} */
WeatherJson;
/** @type {number} */
ItemsTotal;
/** @type {number} */
ItemsPassed;
/** @type {number} */
ItemsFailed;
/** @type {string} */
Outcome;
/** @type {string} */
OutcomeNotes;
/** @type {?number} */
ReinspectionOfInspectionID;
/** @type {?number} */
QcHoldPointID;
/** @type {?string} */
ReportAttachmentId;
/** @type {number} */
RequestCount;
/** @type {number} */
SignatureCount;
/** @type {string} */
CreatedBy;
/** @type {?string} */
CreatedAt;
/** @type {?string} */
UpdatedAt;
/** @type {InspectionItem[]} */
Items = [];
/** @type {InspectionRequest[]} */
Requests = [];
/** @type {SignatureRecord[]} */
Signatures = [];
/** @type {string[]} */
Actions = [];
}
export class InspectionResponse {
/** @param {{ResponseStatus?:ResponseStatus,Inspection?:Inspection}} [init] */
constructor(init) { Object.assign(this, init) }
/** @type {ResponseStatus} */
ResponseStatus;
/** @type {Inspection} */
Inspection;
}
export class InspectionDetailRequest {
/** @param {{InspectionUID?:string}} [init] */
constructor(init) { Object.assign(this, init) }
/** @type {string} */
InspectionUID;
}
JavaScript InspectionDetailRequest DTOs
To override the Content-type in your clients, use the HTTP Accept Header, append the .jsv suffix or ?format=jsv
The following are sample HTTP requests and responses. The placeholders shown need to be replaced with actual values.
GET /v1/inspections/{InspectionUID} HTTP/1.1
Host: api.dev.dynamics.trendsic.com
Accept: text/jsv
HTTP/1.1 200 OK
Content-Type: text/jsv
Content-Length: length
{
ResponseStatus:
{
ErrorCode: String,
Message: String,
StackTrace: String,
Errors:
[
{
ErrorCode: String,
FieldName: String,
Message: String,
Meta:
{
String: String
}
}
],
Meta:
{
String: String
}
},
Inspection:
{
InspectionID: 0,
InspectionUID: 00000000000000000000000000000000,
ProjectID: 0,
ProjectName: String,
JobID: 0,
JobName: String,
InspectionNo: String,
Type: String,
Title: String,
Status: String,
TemplateUID: 00000000000000000000000000000000,
TemplateVersionNo: 0,
ScheduledFor: 0001-01-01,
StartedAt: 0001-01-01,
CompletedAt: 0001-01-01,
ClosedAt: 0001-01-01,
InspectorContactID: 0,
InspectorName: String,
AgencyName: String,
PermitNo: String,
LocationText: String,
Notes: String,
WeatherJson: String,
ItemsTotal: 0,
ItemsPassed: 0,
ItemsFailed: 0,
Outcome: String,
OutcomeNotes: String,
ReinspectionOfInspectionID: 0,
QcHoldPointID: 0,
ReportAttachmentId: 00000000000000000000000000000000,
RequestCount: 0,
SignatureCount: 0,
CreatedBy: String,
CreatedAt: 0001-01-01,
UpdatedAt: 0001-01-01,
Items:
[
{
InspectionItemID: 0,
InspectionID: 0,
Seq: 0,
Section: String,
Prompt: String,
ResponseType: String,
IsRequired: False,
Unit: String,
Guidance: String,
Result: String,
Value: String,
Notes: String,
PhotoCount: 0,
LinkedPunchItemID: 0,
LinkedPunchNo: String,
LinkedPunchStatus: String,
LinkedNcrID: 0,
LinkedNcrNo: String,
LinkedActionID: 0,
AnsweredBy: String,
AnsweredAt: 0001-01-01,
Photos:
[
{
AttachmentId: 00000000000000000000000000000000,
FileName: String,
Url: String,
CreatedBy: String,
CreatedDate: 0001-01-01,
HasAnnotation: False,
AnnotatedAttachmentId: 00000000000000000000000000000000,
AnnotatedUrl: String
}
]
}
],
Requests:
[
{
InspectionRequestID: 0,
InspectionID: 0,
Agency: String,
ContactName: String,
ContactPhone: String,
PermitNo: String,
RequestedDate: 0001-01-01,
RequestedWindow: String,
Status: String,
ConfirmationNo: String,
Outcome: String,
CreatedBy: String,
CreatedAt: 0001-01-01,
UpdatedAt: 0001-01-01
}
],
Signatures:
[
{
SignatureRecordID: 0,
EntityType: String,
EntityID: 0,
Role: String,
SignerName: String,
SignerContactID: 0,
SignerUserId: String,
Method: String,
ImageAttachmentId: 00000000000000000000000000000000,
ImageUrl: String,
ImageHash: String,
DocumentHash: String,
ConsentText: String,
IpAddress: String,
UserAgent: String,
SignedAt: 0001-01-01
}
],
Actions:
[
String
]
}
}