| GET,OPTIONS | /v1/inspections/{InspectionUID} |
|---|
export class InspectionPhoto
{
public AttachmentId: string;
public FileName: string;
public Url: string;
public CreatedBy: string;
public CreatedDate?: string;
public HasAnnotation: boolean;
public AnnotatedAttachmentId?: string;
public AnnotatedUrl: string;
public constructor(init?: Partial<InspectionPhoto>) { (Object as any).assign(this, init); }
}
export class InspectionItem
{
public InspectionItemID: number;
public InspectionID: number;
public Seq: number;
public Section: string;
public Prompt: string;
public ResponseType: string;
public IsRequired: boolean;
public Unit: string;
public Guidance: string;
public Result: string;
public Value: string;
public Notes: string;
public PhotoCount: number;
public LinkedPunchItemID?: number;
public LinkedPunchNo: string;
public LinkedPunchStatus: string;
public LinkedNcrID?: number;
public LinkedNcrNo: string;
public LinkedActionID?: number;
public AnsweredBy: string;
public AnsweredAt?: string;
public Photos: InspectionPhoto[] = [];
public constructor(init?: Partial<InspectionItem>) { (Object as any).assign(this, init); }
}
export class InspectionRequest
{
public InspectionRequestID: number;
public InspectionID: number;
public Agency: string;
public ContactName: string;
public ContactPhone: string;
public PermitNo: string;
public RequestedDate?: string;
public RequestedWindow: string;
public Status: string;
public ConfirmationNo: string;
public Outcome: string;
public CreatedBy: string;
public CreatedAt?: string;
public UpdatedAt?: string;
public constructor(init?: Partial<InspectionRequest>) { (Object as any).assign(this, init); }
}
export class SignatureRecord
{
public SignatureRecordID: number;
public EntityType: string;
public EntityID: number;
public Role: string;
public SignerName: string;
public SignerContactID?: number;
public SignerUserId: string;
public Method: string;
public ImageAttachmentId?: string;
public ImageUrl: string;
public ImageHash: string;
public DocumentHash: string;
public ConsentText: string;
public IpAddress: string;
public UserAgent: string;
public SignedAt?: string;
public constructor(init?: Partial<SignatureRecord>) { (Object as any).assign(this, init); }
}
export class Inspection
{
public InspectionID: number;
public InspectionUID: string;
public ProjectID: number;
public ProjectName: string;
public JobID?: number;
public JobName: string;
public InspectionNo: string;
public Type: string;
public Title: string;
public Status: string;
public TemplateUID?: string;
public TemplateVersionNo?: number;
public ScheduledFor?: string;
public StartedAt?: string;
public CompletedAt?: string;
public ClosedAt?: string;
public InspectorContactID?: number;
public InspectorName: string;
public AgencyName: string;
public PermitNo: string;
public LocationText: string;
public Notes: string;
public WeatherJson: string;
public ItemsTotal: number;
public ItemsPassed: number;
public ItemsFailed: number;
public Outcome: string;
public OutcomeNotes: string;
public ReinspectionOfInspectionID?: number;
public QcHoldPointID?: number;
public ReportAttachmentId?: string;
public RequestCount: number;
public SignatureCount: number;
public CreatedBy: string;
public CreatedAt?: string;
public UpdatedAt?: string;
public Items: InspectionItem[] = [];
public Requests: InspectionRequest[] = [];
public Signatures: SignatureRecord[] = [];
public Actions: string[] = [];
public constructor(init?: Partial<Inspection>) { (Object as any).assign(this, init); }
}
export class InspectionResponse
{
public ResponseStatus: ResponseStatus;
public Inspection: Inspection;
public constructor(init?: Partial<InspectionResponse>) { (Object as any).assign(this, init); }
}
export class InspectionDetailRequest
{
public InspectionUID: string;
public constructor(init?: Partial<InspectionDetailRequest>) { (Object as any).assign(this, init); }
}
TypeScript InspectionDetailRequest DTOs
To override the Content-type in your clients, use the HTTP Accept Header, append the .jsv suffix or ?format=jsv
The following are sample HTTP requests and responses. The placeholders shown need to be replaced with actual values.
GET /v1/inspections/{InspectionUID} HTTP/1.1
Host: api.dev.dynamics.trendsic.com
Accept: text/jsv
HTTP/1.1 200 OK
Content-Type: text/jsv
Content-Length: length
{
ResponseStatus:
{
ErrorCode: String,
Message: String,
StackTrace: String,
Errors:
[
{
ErrorCode: String,
FieldName: String,
Message: String,
Meta:
{
String: String
}
}
],
Meta:
{
String: String
}
},
Inspection:
{
InspectionID: 0,
InspectionUID: 00000000000000000000000000000000,
ProjectID: 0,
ProjectName: String,
JobID: 0,
JobName: String,
InspectionNo: String,
Type: String,
Title: String,
Status: String,
TemplateUID: 00000000000000000000000000000000,
TemplateVersionNo: 0,
ScheduledFor: 0001-01-01,
StartedAt: 0001-01-01,
CompletedAt: 0001-01-01,
ClosedAt: 0001-01-01,
InspectorContactID: 0,
InspectorName: String,
AgencyName: String,
PermitNo: String,
LocationText: String,
Notes: String,
WeatherJson: String,
ItemsTotal: 0,
ItemsPassed: 0,
ItemsFailed: 0,
Outcome: String,
OutcomeNotes: String,
ReinspectionOfInspectionID: 0,
QcHoldPointID: 0,
ReportAttachmentId: 00000000000000000000000000000000,
RequestCount: 0,
SignatureCount: 0,
CreatedBy: String,
CreatedAt: 0001-01-01,
UpdatedAt: 0001-01-01,
Items:
[
{
InspectionItemID: 0,
InspectionID: 0,
Seq: 0,
Section: String,
Prompt: String,
ResponseType: String,
IsRequired: False,
Unit: String,
Guidance: String,
Result: String,
Value: String,
Notes: String,
PhotoCount: 0,
LinkedPunchItemID: 0,
LinkedPunchNo: String,
LinkedPunchStatus: String,
LinkedNcrID: 0,
LinkedNcrNo: String,
LinkedActionID: 0,
AnsweredBy: String,
AnsweredAt: 0001-01-01,
Photos:
[
{
AttachmentId: 00000000000000000000000000000000,
FileName: String,
Url: String,
CreatedBy: String,
CreatedDate: 0001-01-01,
HasAnnotation: False,
AnnotatedAttachmentId: 00000000000000000000000000000000,
AnnotatedUrl: String
}
]
}
],
Requests:
[
{
InspectionRequestID: 0,
InspectionID: 0,
Agency: String,
ContactName: String,
ContactPhone: String,
PermitNo: String,
RequestedDate: 0001-01-01,
RequestedWindow: String,
Status: String,
ConfirmationNo: String,
Outcome: String,
CreatedBy: String,
CreatedAt: 0001-01-01,
UpdatedAt: 0001-01-01
}
],
Signatures:
[
{
SignatureRecordID: 0,
EntityType: String,
EntityID: 0,
Role: String,
SignerName: String,
SignerContactID: 0,
SignerUserId: String,
Method: String,
ImageAttachmentId: 00000000000000000000000000000000,
ImageUrl: String,
ImageHash: String,
DocumentHash: String,
ConsentText: String,
IpAddress: String,
UserAgent: String,
SignedAt: 0001-01-01
}
],
Actions:
[
String
]
}
}