| GET,OPTIONS | /v1/inspections/{InspectionUID} |
|---|
import java.math.*
import java.util.*
import java.io.InputStream
import net.servicestack.client.*
open class InspectionDetailRequest
{
open var InspectionUID:UUID? = null
}
open class InspectionResponse
{
open var ResponseStatus:ResponseStatus? = null
open var Inspection:Inspection? = null
}
open class Inspection
{
open var InspectionID:Int? = null
open var InspectionUID:UUID? = null
open var ProjectID:Int? = null
open var ProjectName:String? = null
open var JobID:Int? = null
open var JobName:String? = null
open var InspectionNo:String? = null
open var Type:String? = null
open var Title:String? = null
open var Status:String? = null
open var TemplateUID:UUID? = null
open var TemplateVersionNo:Int? = null
open var ScheduledFor:Date? = null
open var StartedAt:Date? = null
open var CompletedAt:Date? = null
open var ClosedAt:Date? = null
open var InspectorContactID:Int? = null
open var InspectorName:String? = null
open var AgencyName:String? = null
open var PermitNo:String? = null
open var LocationText:String? = null
open var Notes:String? = null
open var WeatherJson:String? = null
open var ItemsTotal:Int? = null
open var ItemsPassed:Int? = null
open var ItemsFailed:Int? = null
open var Outcome:String? = null
open var OutcomeNotes:String? = null
open var ReinspectionOfInspectionID:Int? = null
open var QcHoldPointID:Int? = null
open var ReportAttachmentId:UUID? = null
open var RequestCount:Int? = null
open var SignatureCount:Int? = null
open var CreatedBy:String? = null
open var CreatedAt:Date? = null
open var UpdatedAt:Date? = null
open var Items:ArrayList<InspectionItem> = ArrayList<InspectionItem>()
open var Requests:ArrayList<InspectionRequest> = ArrayList<InspectionRequest>()
open var Signatures:ArrayList<SignatureRecord> = ArrayList<SignatureRecord>()
open var Actions:ArrayList<String> = ArrayList<String>()
}
open class InspectionItem
{
open var InspectionItemID:Int? = null
open var InspectionID:Int? = null
open var Seq:Int? = null
open var Section:String? = null
open var Prompt:String? = null
open var ResponseType:String? = null
open var IsRequired:Boolean? = null
open var Unit:String? = null
open var Guidance:String? = null
open var Result:String? = null
open var Value:String? = null
open var Notes:String? = null
open var PhotoCount:Int? = null
open var LinkedPunchItemID:Int? = null
open var LinkedPunchNo:String? = null
open var LinkedPunchStatus:String? = null
open var LinkedNcrID:Int? = null
open var LinkedNcrNo:String? = null
open var LinkedActionID:Int? = null
open var AnsweredBy:String? = null
open var AnsweredAt:Date? = null
open var Photos:ArrayList<InspectionPhoto> = ArrayList<InspectionPhoto>()
}
open class InspectionPhoto
{
open var AttachmentId:UUID? = null
open var FileName:String? = null
open var Url:String? = null
open var CreatedBy:String? = null
open var CreatedDate:Date? = null
open var HasAnnotation:Boolean? = null
open var AnnotatedAttachmentId:UUID? = null
open var AnnotatedUrl:String? = null
}
open class InspectionRequest
{
open var InspectionRequestID:Int? = null
open var InspectionID:Int? = null
open var Agency:String? = null
open var ContactName:String? = null
open var ContactPhone:String? = null
open var PermitNo:String? = null
open var RequestedDate:Date? = null
open var RequestedWindow:String? = null
open var Status:String? = null
open var ConfirmationNo:String? = null
open var Outcome:String? = null
open var CreatedBy:String? = null
open var CreatedAt:Date? = null
open var UpdatedAt:Date? = null
}
open class SignatureRecord
{
open var SignatureRecordID:Int? = null
open var EntityType:String? = null
open var EntityID:Int? = null
open var Role:String? = null
open var SignerName:String? = null
open var SignerContactID:Int? = null
open var SignerUserId:String? = null
open var Method:String? = null
open var ImageAttachmentId:UUID? = null
open var ImageUrl:String? = null
open var ImageHash:String? = null
open var DocumentHash:String? = null
open var ConsentText:String? = null
open var IpAddress:String? = null
open var UserAgent:String? = null
open var SignedAt:Date? = null
}
Kotlin InspectionDetailRequest DTOs
To override the Content-type in your clients, use the HTTP Accept Header, append the .xml suffix or ?format=xml
The following are sample HTTP requests and responses. The placeholders shown need to be replaced with actual values.
GET /v1/inspections/{InspectionUID} HTTP/1.1
Host: api.dev.dynamics.trendsic.com
Accept: application/xml
HTTP/1.1 200 OK
Content-Type: application/xml
Content-Length: length
<InspectionResponse xmlns:i="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://schemas.datacontract.org/2004/07/CRM.AgencyPlatform.API.Internal">
<Inspection>
<Actions xmlns:d3p1="http://schemas.microsoft.com/2003/10/Serialization/Arrays">
<d3p1:string>String</d3p1:string>
</Actions>
<AgencyName>String</AgencyName>
<ClosedAt>0001-01-01T00:00:00</ClosedAt>
<CompletedAt>0001-01-01T00:00:00</CompletedAt>
<CreatedAt>0001-01-01T00:00:00</CreatedAt>
<CreatedBy>String</CreatedBy>
<InspectionID>0</InspectionID>
<InspectionNo>String</InspectionNo>
<InspectionUID>00000000-0000-0000-0000-000000000000</InspectionUID>
<InspectorContactID>0</InspectorContactID>
<InspectorName>String</InspectorName>
<Items>
<InspectionItem>
<AnsweredAt>0001-01-01T00:00:00</AnsweredAt>
<AnsweredBy>String</AnsweredBy>
<Guidance>String</Guidance>
<InspectionID>0</InspectionID>
<InspectionItemID>0</InspectionItemID>
<IsRequired>false</IsRequired>
<LinkedActionID>0</LinkedActionID>
<LinkedNcrID>0</LinkedNcrID>
<LinkedNcrNo>String</LinkedNcrNo>
<LinkedPunchItemID>0</LinkedPunchItemID>
<LinkedPunchNo>String</LinkedPunchNo>
<LinkedPunchStatus>String</LinkedPunchStatus>
<Notes>String</Notes>
<PhotoCount>0</PhotoCount>
<Photos>
<InspectionPhoto>
<AnnotatedAttachmentId>00000000-0000-0000-0000-000000000000</AnnotatedAttachmentId>
<AnnotatedUrl>String</AnnotatedUrl>
<AttachmentId>00000000-0000-0000-0000-000000000000</AttachmentId>
<CreatedBy>String</CreatedBy>
<CreatedDate>0001-01-01T00:00:00</CreatedDate>
<FileName>String</FileName>
<HasAnnotation>false</HasAnnotation>
<Url>String</Url>
</InspectionPhoto>
</Photos>
<Prompt>String</Prompt>
<ResponseType>String</ResponseType>
<Result>String</Result>
<Section>String</Section>
<Seq>0</Seq>
<Unit>String</Unit>
<Value>String</Value>
</InspectionItem>
</Items>
<ItemsFailed>0</ItemsFailed>
<ItemsPassed>0</ItemsPassed>
<ItemsTotal>0</ItemsTotal>
<JobID>0</JobID>
<JobName>String</JobName>
<LocationText>String</LocationText>
<Notes>String</Notes>
<Outcome>String</Outcome>
<OutcomeNotes>String</OutcomeNotes>
<PermitNo>String</PermitNo>
<ProjectID>0</ProjectID>
<ProjectName>String</ProjectName>
<QcHoldPointID>0</QcHoldPointID>
<ReinspectionOfInspectionID>0</ReinspectionOfInspectionID>
<ReportAttachmentId>00000000-0000-0000-0000-000000000000</ReportAttachmentId>
<RequestCount>0</RequestCount>
<Requests>
<InspectionRequest>
<Agency>String</Agency>
<ConfirmationNo>String</ConfirmationNo>
<ContactName>String</ContactName>
<ContactPhone>String</ContactPhone>
<CreatedAt>0001-01-01T00:00:00</CreatedAt>
<CreatedBy>String</CreatedBy>
<InspectionID>0</InspectionID>
<InspectionRequestID>0</InspectionRequestID>
<Outcome>String</Outcome>
<PermitNo>String</PermitNo>
<RequestedDate>0001-01-01T00:00:00</RequestedDate>
<RequestedWindow>String</RequestedWindow>
<Status>String</Status>
<UpdatedAt>0001-01-01T00:00:00</UpdatedAt>
</InspectionRequest>
</Requests>
<ScheduledFor>0001-01-01T00:00:00</ScheduledFor>
<SignatureCount>0</SignatureCount>
<Signatures>
<SignatureRecord>
<ConsentText>String</ConsentText>
<DocumentHash>String</DocumentHash>
<EntityID>0</EntityID>
<EntityType>String</EntityType>
<ImageAttachmentId>00000000-0000-0000-0000-000000000000</ImageAttachmentId>
<ImageHash>String</ImageHash>
<ImageUrl>String</ImageUrl>
<IpAddress>String</IpAddress>
<Method>String</Method>
<Role>String</Role>
<SignatureRecordID>0</SignatureRecordID>
<SignedAt>0001-01-01T00:00:00</SignedAt>
<SignerContactID>0</SignerContactID>
<SignerName>String</SignerName>
<SignerUserId>String</SignerUserId>
<UserAgent>String</UserAgent>
</SignatureRecord>
</Signatures>
<StartedAt>0001-01-01T00:00:00</StartedAt>
<Status>String</Status>
<TemplateUID>00000000-0000-0000-0000-000000000000</TemplateUID>
<TemplateVersionNo>0</TemplateVersionNo>
<Title>String</Title>
<Type>String</Type>
<UpdatedAt>0001-01-01T00:00:00</UpdatedAt>
<WeatherJson>String</WeatherJson>
</Inspection>
<ResponseStatus xmlns:d2p1="http://schemas.servicestack.net/types">
<d2p1:ErrorCode>String</d2p1:ErrorCode>
<d2p1:Message>String</d2p1:Message>
<d2p1:StackTrace>String</d2p1:StackTrace>
<d2p1:Errors>
<d2p1:ResponseError>
<d2p1:ErrorCode>String</d2p1:ErrorCode>
<d2p1:FieldName>String</d2p1:FieldName>
<d2p1:Message>String</d2p1:Message>
<d2p1:Meta xmlns:d5p1="http://schemas.microsoft.com/2003/10/Serialization/Arrays">
<d5p1:KeyValueOfstringstring>
<d5p1:Key>String</d5p1:Key>
<d5p1:Value>String</d5p1:Value>
</d5p1:KeyValueOfstringstring>
</d2p1:Meta>
</d2p1:ResponseError>
</d2p1:Errors>
<d2p1:Meta xmlns:d3p1="http://schemas.microsoft.com/2003/10/Serialization/Arrays">
<d3p1:KeyValueOfstringstring>
<d3p1:Key>String</d3p1:Key>
<d3p1:Value>String</d3p1:Value>
</d3p1:KeyValueOfstringstring>
</d2p1:Meta>
</ResponseStatus>
</InspectionResponse>