Trendsic Platform Service

<back to all web services

InspectionDetailRequest

Requires Authentication
The following routes are available for this service:
GET,OPTIONS/v1/inspections/{InspectionUID}
import datetime
import decimal
from marshmallow.fields import *
from servicestack import *
from typing import *
from dataclasses import dataclass, field
from dataclasses_json import dataclass_json, LetterCase, Undefined, config
from enum import Enum, IntEnum


@dataclass_json(letter_case=LetterCase.CAMEL, undefined=Undefined.EXCLUDE)
@dataclass
class InspectionPhoto:
    attachment_id: Optional[str] = None
    file_name: Optional[str] = None
    url: Optional[str] = None
    created_by: Optional[str] = None
    created_date: Optional[datetime.datetime] = None
    has_annotation: bool = False
    annotated_attachment_id: Optional[str] = None
    annotated_url: Optional[str] = None


@dataclass_json(letter_case=LetterCase.CAMEL, undefined=Undefined.EXCLUDE)
@dataclass
class InspectionItem:
    inspection_item_i_d: int = 0
    inspection_i_d: int = 0
    seq: int = 0
    section: Optional[str] = None
    prompt: Optional[str] = None
    response_type: Optional[str] = None
    is_required: bool = False
    unit: Optional[str] = None
    guidance: Optional[str] = None
    result: Optional[str] = None
    value: Optional[str] = None
    notes: Optional[str] = None
    photo_count: int = 0
    linked_punch_item_i_d: Optional[int] = None
    linked_punch_no: Optional[str] = None
    linked_punch_status: Optional[str] = None
    linked_ncr_i_d: Optional[int] = None
    linked_ncr_no: Optional[str] = None
    linked_action_i_d: Optional[int] = None
    answered_by: Optional[str] = None
    answered_at: Optional[datetime.datetime] = None
    photos: List[InspectionPhoto] = field(default_factory=list)


@dataclass_json(letter_case=LetterCase.CAMEL, undefined=Undefined.EXCLUDE)
@dataclass
class InspectionRequest:
    inspection_request_i_d: int = 0
    inspection_i_d: int = 0
    agency: Optional[str] = None
    contact_name: Optional[str] = None
    contact_phone: Optional[str] = None
    permit_no: Optional[str] = None
    requested_date: Optional[datetime.datetime] = None
    requested_window: Optional[str] = None
    status: Optional[str] = None
    confirmation_no: Optional[str] = None
    outcome: Optional[str] = None
    created_by: Optional[str] = None
    created_at: Optional[datetime.datetime] = None
    updated_at: Optional[datetime.datetime] = None


@dataclass_json(letter_case=LetterCase.CAMEL, undefined=Undefined.EXCLUDE)
@dataclass
class SignatureRecord:
    signature_record_i_d: int = 0
    entity_type: Optional[str] = None
    entity_i_d: int = 0
    role: Optional[str] = None
    signer_name: Optional[str] = None
    signer_contact_i_d: Optional[int] = None
    signer_user_id: Optional[str] = None
    method: Optional[str] = None
    image_attachment_id: Optional[str] = None
    image_url: Optional[str] = None
    image_hash: Optional[str] = None
    document_hash: Optional[str] = None
    consent_text: Optional[str] = None
    ip_address: Optional[str] = None
    user_agent: Optional[str] = None
    signed_at: Optional[datetime.datetime] = None


@dataclass_json(letter_case=LetterCase.CAMEL, undefined=Undefined.EXCLUDE)
@dataclass
class Inspection:
    inspection_i_d: int = 0
    inspection_u_i_d: Optional[str] = None
    project_i_d: int = 0
    project_name: Optional[str] = None
    job_i_d: Optional[int] = None
    job_name: Optional[str] = None
    inspection_no: Optional[str] = None
    type: Optional[str] = None
    title: Optional[str] = None
    status: Optional[str] = None
    template_u_i_d: Optional[str] = None
    template_version_no: Optional[int] = None
    scheduled_for: Optional[datetime.datetime] = None
    started_at: Optional[datetime.datetime] = None
    completed_at: Optional[datetime.datetime] = None
    closed_at: Optional[datetime.datetime] = None
    inspector_contact_i_d: Optional[int] = None
    inspector_name: Optional[str] = None
    agency_name: Optional[str] = None
    permit_no: Optional[str] = None
    location_text: Optional[str] = None
    notes: Optional[str] = None
    weather_json: Optional[str] = None
    items_total: int = 0
    items_passed: int = 0
    items_failed: int = 0
    outcome: Optional[str] = None
    outcome_notes: Optional[str] = None
    reinspection_of_inspection_i_d: Optional[int] = None
    qc_hold_point_i_d: Optional[int] = None
    report_attachment_id: Optional[str] = None
    request_count: int = 0
    signature_count: int = 0
    created_by: Optional[str] = None
    created_at: Optional[datetime.datetime] = None
    updated_at: Optional[datetime.datetime] = None
    items: List[InspectionItem] = field(default_factory=list)
    requests: List[InspectionRequest] = field(default_factory=list)
    signatures: List[SignatureRecord] = field(default_factory=list)
    actions: List[str] = field(default_factory=list)


@dataclass_json(letter_case=LetterCase.CAMEL, undefined=Undefined.EXCLUDE)
@dataclass
class InspectionResponse:
    response_status: Optional[ResponseStatus] = None
    inspection: Optional[Inspection] = None


@dataclass_json(letter_case=LetterCase.CAMEL, undefined=Undefined.EXCLUDE)
@dataclass
class InspectionDetailRequest:
    inspection_u_i_d: Optional[str] = None

Python InspectionDetailRequest DTOs

To override the Content-type in your clients, use the HTTP Accept Header, append the .xml suffix or ?format=xml

HTTP + XML

The following are sample HTTP requests and responses. The placeholders shown need to be replaced with actual values.

GET /v1/inspections/{InspectionUID} HTTP/1.1 
Host: api.dev.dynamics.trendsic.com 
Accept: application/xml
HTTP/1.1 200 OK
Content-Type: application/xml
Content-Length: length

<InspectionResponse xmlns:i="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://schemas.datacontract.org/2004/07/CRM.AgencyPlatform.API.Internal">
  <Inspection>
    <Actions xmlns:d3p1="http://schemas.microsoft.com/2003/10/Serialization/Arrays">
      <d3p1:string>String</d3p1:string>
    </Actions>
    <AgencyName>String</AgencyName>
    <ClosedAt>0001-01-01T00:00:00</ClosedAt>
    <CompletedAt>0001-01-01T00:00:00</CompletedAt>
    <CreatedAt>0001-01-01T00:00:00</CreatedAt>
    <CreatedBy>String</CreatedBy>
    <InspectionID>0</InspectionID>
    <InspectionNo>String</InspectionNo>
    <InspectionUID>00000000-0000-0000-0000-000000000000</InspectionUID>
    <InspectorContactID>0</InspectorContactID>
    <InspectorName>String</InspectorName>
    <Items>
      <InspectionItem>
        <AnsweredAt>0001-01-01T00:00:00</AnsweredAt>
        <AnsweredBy>String</AnsweredBy>
        <Guidance>String</Guidance>
        <InspectionID>0</InspectionID>
        <InspectionItemID>0</InspectionItemID>
        <IsRequired>false</IsRequired>
        <LinkedActionID>0</LinkedActionID>
        <LinkedNcrID>0</LinkedNcrID>
        <LinkedNcrNo>String</LinkedNcrNo>
        <LinkedPunchItemID>0</LinkedPunchItemID>
        <LinkedPunchNo>String</LinkedPunchNo>
        <LinkedPunchStatus>String</LinkedPunchStatus>
        <Notes>String</Notes>
        <PhotoCount>0</PhotoCount>
        <Photos>
          <InspectionPhoto>
            <AnnotatedAttachmentId>00000000-0000-0000-0000-000000000000</AnnotatedAttachmentId>
            <AnnotatedUrl>String</AnnotatedUrl>
            <AttachmentId>00000000-0000-0000-0000-000000000000</AttachmentId>
            <CreatedBy>String</CreatedBy>
            <CreatedDate>0001-01-01T00:00:00</CreatedDate>
            <FileName>String</FileName>
            <HasAnnotation>false</HasAnnotation>
            <Url>String</Url>
          </InspectionPhoto>
        </Photos>
        <Prompt>String</Prompt>
        <ResponseType>String</ResponseType>
        <Result>String</Result>
        <Section>String</Section>
        <Seq>0</Seq>
        <Unit>String</Unit>
        <Value>String</Value>
      </InspectionItem>
    </Items>
    <ItemsFailed>0</ItemsFailed>
    <ItemsPassed>0</ItemsPassed>
    <ItemsTotal>0</ItemsTotal>
    <JobID>0</JobID>
    <JobName>String</JobName>
    <LocationText>String</LocationText>
    <Notes>String</Notes>
    <Outcome>String</Outcome>
    <OutcomeNotes>String</OutcomeNotes>
    <PermitNo>String</PermitNo>
    <ProjectID>0</ProjectID>
    <ProjectName>String</ProjectName>
    <QcHoldPointID>0</QcHoldPointID>
    <ReinspectionOfInspectionID>0</ReinspectionOfInspectionID>
    <ReportAttachmentId>00000000-0000-0000-0000-000000000000</ReportAttachmentId>
    <RequestCount>0</RequestCount>
    <Requests>
      <InspectionRequest>
        <Agency>String</Agency>
        <ConfirmationNo>String</ConfirmationNo>
        <ContactName>String</ContactName>
        <ContactPhone>String</ContactPhone>
        <CreatedAt>0001-01-01T00:00:00</CreatedAt>
        <CreatedBy>String</CreatedBy>
        <InspectionID>0</InspectionID>
        <InspectionRequestID>0</InspectionRequestID>
        <Outcome>String</Outcome>
        <PermitNo>String</PermitNo>
        <RequestedDate>0001-01-01T00:00:00</RequestedDate>
        <RequestedWindow>String</RequestedWindow>
        <Status>String</Status>
        <UpdatedAt>0001-01-01T00:00:00</UpdatedAt>
      </InspectionRequest>
    </Requests>
    <ScheduledFor>0001-01-01T00:00:00</ScheduledFor>
    <SignatureCount>0</SignatureCount>
    <Signatures>
      <SignatureRecord>
        <ConsentText>String</ConsentText>
        <DocumentHash>String</DocumentHash>
        <EntityID>0</EntityID>
        <EntityType>String</EntityType>
        <ImageAttachmentId>00000000-0000-0000-0000-000000000000</ImageAttachmentId>
        <ImageHash>String</ImageHash>
        <ImageUrl>String</ImageUrl>
        <IpAddress>String</IpAddress>
        <Method>String</Method>
        <Role>String</Role>
        <SignatureRecordID>0</SignatureRecordID>
        <SignedAt>0001-01-01T00:00:00</SignedAt>
        <SignerContactID>0</SignerContactID>
        <SignerName>String</SignerName>
        <SignerUserId>String</SignerUserId>
        <UserAgent>String</UserAgent>
      </SignatureRecord>
    </Signatures>
    <StartedAt>0001-01-01T00:00:00</StartedAt>
    <Status>String</Status>
    <TemplateUID>00000000-0000-0000-0000-000000000000</TemplateUID>
    <TemplateVersionNo>0</TemplateVersionNo>
    <Title>String</Title>
    <Type>String</Type>
    <UpdatedAt>0001-01-01T00:00:00</UpdatedAt>
    <WeatherJson>String</WeatherJson>
  </Inspection>
  <ResponseStatus xmlns:d2p1="http://schemas.servicestack.net/types">
    <d2p1:ErrorCode>String</d2p1:ErrorCode>
    <d2p1:Message>String</d2p1:Message>
    <d2p1:StackTrace>String</d2p1:StackTrace>
    <d2p1:Errors>
      <d2p1:ResponseError>
        <d2p1:ErrorCode>String</d2p1:ErrorCode>
        <d2p1:FieldName>String</d2p1:FieldName>
        <d2p1:Message>String</d2p1:Message>
        <d2p1:Meta xmlns:d5p1="http://schemas.microsoft.com/2003/10/Serialization/Arrays">
          <d5p1:KeyValueOfstringstring>
            <d5p1:Key>String</d5p1:Key>
            <d5p1:Value>String</d5p1:Value>
          </d5p1:KeyValueOfstringstring>
        </d2p1:Meta>
      </d2p1:ResponseError>
    </d2p1:Errors>
    <d2p1:Meta xmlns:d3p1="http://schemas.microsoft.com/2003/10/Serialization/Arrays">
      <d3p1:KeyValueOfstringstring>
        <d3p1:Key>String</d3p1:Key>
        <d3p1:Value>String</d3p1:Value>
      </d3p1:KeyValueOfstringstring>
    </d2p1:Meta>
  </ResponseStatus>
</InspectionResponse>