| GET,OPTIONS | /v1/inspections/{InspectionUID} |
|---|
export class InspectionPhoto
{
public AttachmentId: string;
public FileName: string;
public Url: string;
public CreatedBy: string;
public CreatedDate?: string;
public HasAnnotation: boolean;
public AnnotatedAttachmentId?: string;
public AnnotatedUrl: string;
public constructor(init?: Partial<InspectionPhoto>) { (Object as any).assign(this, init); }
}
export class InspectionItem
{
public InspectionItemID: number;
public InspectionID: number;
public Seq: number;
public Section: string;
public Prompt: string;
public ResponseType: string;
public IsRequired: boolean;
public Unit: string;
public Guidance: string;
public Result: string;
public Value: string;
public Notes: string;
public PhotoCount: number;
public LinkedPunchItemID?: number;
public LinkedPunchNo: string;
public LinkedPunchStatus: string;
public LinkedNcrID?: number;
public LinkedNcrNo: string;
public LinkedActionID?: number;
public AnsweredBy: string;
public AnsweredAt?: string;
public Photos: InspectionPhoto[] = [];
public constructor(init?: Partial<InspectionItem>) { (Object as any).assign(this, init); }
}
export class InspectionRequest
{
public InspectionRequestID: number;
public InspectionID: number;
public Agency: string;
public ContactName: string;
public ContactPhone: string;
public PermitNo: string;
public RequestedDate?: string;
public RequestedWindow: string;
public Status: string;
public ConfirmationNo: string;
public Outcome: string;
public CreatedBy: string;
public CreatedAt?: string;
public UpdatedAt?: string;
public constructor(init?: Partial<InspectionRequest>) { (Object as any).assign(this, init); }
}
export class SignatureRecord
{
public SignatureRecordID: number;
public EntityType: string;
public EntityID: number;
public Role: string;
public SignerName: string;
public SignerContactID?: number;
public SignerUserId: string;
public Method: string;
public ImageAttachmentId?: string;
public ImageUrl: string;
public ImageHash: string;
public DocumentHash: string;
public ConsentText: string;
public IpAddress: string;
public UserAgent: string;
public SignedAt?: string;
public constructor(init?: Partial<SignatureRecord>) { (Object as any).assign(this, init); }
}
export class Inspection
{
public InspectionID: number;
public InspectionUID: string;
public ProjectID: number;
public ProjectName: string;
public JobID?: number;
public JobName: string;
public InspectionNo: string;
public Type: string;
public Title: string;
public Status: string;
public TemplateUID?: string;
public TemplateVersionNo?: number;
public ScheduledFor?: string;
public StartedAt?: string;
public CompletedAt?: string;
public ClosedAt?: string;
public InspectorContactID?: number;
public InspectorName: string;
public AgencyName: string;
public PermitNo: string;
public LocationText: string;
public Notes: string;
public WeatherJson: string;
public ItemsTotal: number;
public ItemsPassed: number;
public ItemsFailed: number;
public Outcome: string;
public OutcomeNotes: string;
public ReinspectionOfInspectionID?: number;
public QcHoldPointID?: number;
public ReportAttachmentId?: string;
public RequestCount: number;
public SignatureCount: number;
public CreatedBy: string;
public CreatedAt?: string;
public UpdatedAt?: string;
public Items: InspectionItem[] = [];
public Requests: InspectionRequest[] = [];
public Signatures: SignatureRecord[] = [];
public Actions: string[] = [];
public constructor(init?: Partial<Inspection>) { (Object as any).assign(this, init); }
}
export class InspectionResponse
{
public ResponseStatus: ResponseStatus;
public Inspection: Inspection;
public constructor(init?: Partial<InspectionResponse>) { (Object as any).assign(this, init); }
}
export class InspectionDetailRequest
{
public InspectionUID: string;
public constructor(init?: Partial<InspectionDetailRequest>) { (Object as any).assign(this, init); }
}
TypeScript InspectionDetailRequest DTOs
To override the Content-type in your clients, use the HTTP Accept Header, append the .xml suffix or ?format=xml
The following are sample HTTP requests and responses. The placeholders shown need to be replaced with actual values.
GET /v1/inspections/{InspectionUID} HTTP/1.1
Host: api.dev.dynamics.trendsic.com
Accept: application/xml
HTTP/1.1 200 OK
Content-Type: application/xml
Content-Length: length
<InspectionResponse xmlns:i="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://schemas.datacontract.org/2004/07/CRM.AgencyPlatform.API.Internal">
<Inspection>
<Actions xmlns:d3p1="http://schemas.microsoft.com/2003/10/Serialization/Arrays">
<d3p1:string>String</d3p1:string>
</Actions>
<AgencyName>String</AgencyName>
<ClosedAt>0001-01-01T00:00:00</ClosedAt>
<CompletedAt>0001-01-01T00:00:00</CompletedAt>
<CreatedAt>0001-01-01T00:00:00</CreatedAt>
<CreatedBy>String</CreatedBy>
<InspectionID>0</InspectionID>
<InspectionNo>String</InspectionNo>
<InspectionUID>00000000-0000-0000-0000-000000000000</InspectionUID>
<InspectorContactID>0</InspectorContactID>
<InspectorName>String</InspectorName>
<Items>
<InspectionItem>
<AnsweredAt>0001-01-01T00:00:00</AnsweredAt>
<AnsweredBy>String</AnsweredBy>
<Guidance>String</Guidance>
<InspectionID>0</InspectionID>
<InspectionItemID>0</InspectionItemID>
<IsRequired>false</IsRequired>
<LinkedActionID>0</LinkedActionID>
<LinkedNcrID>0</LinkedNcrID>
<LinkedNcrNo>String</LinkedNcrNo>
<LinkedPunchItemID>0</LinkedPunchItemID>
<LinkedPunchNo>String</LinkedPunchNo>
<LinkedPunchStatus>String</LinkedPunchStatus>
<Notes>String</Notes>
<PhotoCount>0</PhotoCount>
<Photos>
<InspectionPhoto>
<AnnotatedAttachmentId>00000000-0000-0000-0000-000000000000</AnnotatedAttachmentId>
<AnnotatedUrl>String</AnnotatedUrl>
<AttachmentId>00000000-0000-0000-0000-000000000000</AttachmentId>
<CreatedBy>String</CreatedBy>
<CreatedDate>0001-01-01T00:00:00</CreatedDate>
<FileName>String</FileName>
<HasAnnotation>false</HasAnnotation>
<Url>String</Url>
</InspectionPhoto>
</Photos>
<Prompt>String</Prompt>
<ResponseType>String</ResponseType>
<Result>String</Result>
<Section>String</Section>
<Seq>0</Seq>
<Unit>String</Unit>
<Value>String</Value>
</InspectionItem>
</Items>
<ItemsFailed>0</ItemsFailed>
<ItemsPassed>0</ItemsPassed>
<ItemsTotal>0</ItemsTotal>
<JobID>0</JobID>
<JobName>String</JobName>
<LocationText>String</LocationText>
<Notes>String</Notes>
<Outcome>String</Outcome>
<OutcomeNotes>String</OutcomeNotes>
<PermitNo>String</PermitNo>
<ProjectID>0</ProjectID>
<ProjectName>String</ProjectName>
<QcHoldPointID>0</QcHoldPointID>
<ReinspectionOfInspectionID>0</ReinspectionOfInspectionID>
<ReportAttachmentId>00000000-0000-0000-0000-000000000000</ReportAttachmentId>
<RequestCount>0</RequestCount>
<Requests>
<InspectionRequest>
<Agency>String</Agency>
<ConfirmationNo>String</ConfirmationNo>
<ContactName>String</ContactName>
<ContactPhone>String</ContactPhone>
<CreatedAt>0001-01-01T00:00:00</CreatedAt>
<CreatedBy>String</CreatedBy>
<InspectionID>0</InspectionID>
<InspectionRequestID>0</InspectionRequestID>
<Outcome>String</Outcome>
<PermitNo>String</PermitNo>
<RequestedDate>0001-01-01T00:00:00</RequestedDate>
<RequestedWindow>String</RequestedWindow>
<Status>String</Status>
<UpdatedAt>0001-01-01T00:00:00</UpdatedAt>
</InspectionRequest>
</Requests>
<ScheduledFor>0001-01-01T00:00:00</ScheduledFor>
<SignatureCount>0</SignatureCount>
<Signatures>
<SignatureRecord>
<ConsentText>String</ConsentText>
<DocumentHash>String</DocumentHash>
<EntityID>0</EntityID>
<EntityType>String</EntityType>
<ImageAttachmentId>00000000-0000-0000-0000-000000000000</ImageAttachmentId>
<ImageHash>String</ImageHash>
<ImageUrl>String</ImageUrl>
<IpAddress>String</IpAddress>
<Method>String</Method>
<Role>String</Role>
<SignatureRecordID>0</SignatureRecordID>
<SignedAt>0001-01-01T00:00:00</SignedAt>
<SignerContactID>0</SignerContactID>
<SignerName>String</SignerName>
<SignerUserId>String</SignerUserId>
<UserAgent>String</UserAgent>
</SignatureRecord>
</Signatures>
<StartedAt>0001-01-01T00:00:00</StartedAt>
<Status>String</Status>
<TemplateUID>00000000-0000-0000-0000-000000000000</TemplateUID>
<TemplateVersionNo>0</TemplateVersionNo>
<Title>String</Title>
<Type>String</Type>
<UpdatedAt>0001-01-01T00:00:00</UpdatedAt>
<WeatherJson>String</WeatherJson>
</Inspection>
<ResponseStatus xmlns:d2p1="http://schemas.servicestack.net/types">
<d2p1:ErrorCode>String</d2p1:ErrorCode>
<d2p1:Message>String</d2p1:Message>
<d2p1:StackTrace>String</d2p1:StackTrace>
<d2p1:Errors>
<d2p1:ResponseError>
<d2p1:ErrorCode>String</d2p1:ErrorCode>
<d2p1:FieldName>String</d2p1:FieldName>
<d2p1:Message>String</d2p1:Message>
<d2p1:Meta xmlns:d5p1="http://schemas.microsoft.com/2003/10/Serialization/Arrays">
<d5p1:KeyValueOfstringstring>
<d5p1:Key>String</d5p1:Key>
<d5p1:Value>String</d5p1:Value>
</d5p1:KeyValueOfstringstring>
</d2p1:Meta>
</d2p1:ResponseError>
</d2p1:Errors>
<d2p1:Meta xmlns:d3p1="http://schemas.microsoft.com/2003/10/Serialization/Arrays">
<d3p1:KeyValueOfstringstring>
<d3p1:Key>String</d3p1:Key>
<d3p1:Value>String</d3p1:Value>
</d3p1:KeyValueOfstringstring>
</d2p1:Meta>
</ResponseStatus>
</InspectionResponse>